Two foot-device quotes can arrive a day apart, describe the same product category, and differ by an amount that makes one of them look like the obvious choice. In this category the gap is almost never arbitrary. It sits in seven specific places, and each one is inspectable if you know to ask. This guide walks through them using the published specifications of the P91A, P91C, P92 and P93 to show what “the same device” actually means.
Line item 1: power and coil architecture
Power rating is the figure buyers compare first, and it is the least informative on its own. The P91A is published at 240 W and the P91C at 200 W, which makes the P91A look stronger. But the P91C’s lower figure comes with a twelve-coil matrix layout, and a matrix is a different engineering answer to a different problem: distributing energy evenly across a footplate rather than concentrating it.
So the question is not “how many watts” but “how is the field distributed, and is that distribution what my market needs”. A single high-power coil and a twelve-coil low-power matrix are not substitutes, and quoting them as if they were is where the first price gap comes from. Our note on coil design and footplate coverage covers how to check this claim with a measurement rather than a datasheet.
Line item 2: frequency and waveform capability
A device that runs one fixed program and a device that sweeps 1–100 Hz across multiple waveform shapes cost different amounts to build, because the second requires a programmable driver and a control board that can drive it. The P91C is published as supporting 1–100 Hz with sine, square and triangular waveform combinations; the P91A is published around its PEMF output with automatic sensing rather than a programmable frequency range.
When a quote claims a frequency range, ask three follow-ups: what the actual delivered waveform looks like at the footplate, whether the range applies to all modes or only the headline one, and how the frequency is verified at final test. Frequency stated without a verification method is a marketing figure.
Line item 3: control interface and usability
Mechanical switch, membrane panel, remote control, LCD display. Each step up is a real cost and each step up is a real product decision. The P91A is built around automatic sensing: the device starts when someone steps on and stops when they step off. The P91C adds a remote control and an LCD screen alongside three intensity levels.
Automatic sensing is not a cost reduction; it is a usability bet aimed at older users who will not read a manual. A remote and a display is a feature bet aimed at households that want visible control. Both are legitimate, and a buyer who prices them as equivalent will choose wrongly. Our P91A buyer guide explains what the automatic-sensing design implies for retail positioning.
Line item 4: penetration depth and thermal design
The P92 is published at 160 W with a stated penetration depth of 4–5 cm. The P93 is published with a conversion efficiency above 90% and a surface temperature held below 40 °C. Those two specifications point at opposite engineering priorities: depth versus thermal safety.
A device that runs cool on its surface while delivering high conversion efficiency has spent money on thermal path design and on the control loop that keeps it there. A device that runs at higher surface temperature has spent less. If you are selling into a market where an older household member uses the device unsupervised, surface temperature is not a detail — it is the specification that decides whether the product is appropriate. The electrical safety and temperature-rise guide sets out how to test it.
Line item 5: safety systems, itemised
Over-temperature protection, over-current protection, automatic shut-off, and — on the P91C — over-heat, over-load and automatic power-cut protection as stated features. These are individually priced and individually omittable. A quote that lists “safety protection” as one line has told you nothing.
Ask for the protections as a numbered list, with the trip point for each. Then compare lists, not prices.
Line item 6: compliance and test scope
Electrical safety and EMC test reports, the language of the manual, the content of the rating label, and whether the reports were issued for the exact configuration you are buying. A report issued for a 230 V build does not cover a 120 V build. A report issued before a control-board change may no longer describe the product being shipped.
This is the single most common reason two quotes differ by a wide margin on what looks like identical hardware: one includes the documentation package and the other offers it separately.
Line item 7: packaging, warranty and spares
Courier-grade versus container-grade cartons, the drop-test basis, whether spare footplates or fuses ship with the order, and the warranty term by component rather than as a single number. Our packaging and transit validation guide shows what a defensible carton specification looks like, and the warranty and after-sales guide covers the term structure.
Putting the seven into one comparison sheet
| Line item | What the low quote typically omits | How to verify |
|---|---|---|
| Power and coil architecture | Uniformity across the footplate | Request a field map or uniformity measurement, not a wattage figure |
| Frequency and waveform | Verification of the delivered waveform | Ask for the final-test record at the footplate |
| Control interface | Usability testing with older users | Ask for the manual and try the sequence yourself |
| Penetration and thermal | Surface temperature under continuous use | Request the temperature-rise result at rated duty |
| Safety systems | Named protections and trip points | Demand an itemised list with thresholds |
| Compliance scope | Reports for the exact voltage build | Check the report’s model and voltage on its first page |
| Packaging, warranty, spares | Drop-test basis and component-level terms | Ask what is in the carton and what the term excludes |
Published commercial terms for this range
The standard terms published across the terahertz and PEMF foot device range are a minimum of 300 units per model, FOB quotation on request, a lead time of 30–45 days after payment with earlier shipment possible when stock is available, and samples on request with terms agreed case by case. Because each model is its own minimum, a four-model range means four commitments unless a trial arrangement is agreed first.
Frequently asked questions
Why is a 200 W device sometimes quoted higher than a 240 W device?
Because wattage is one input to cost, not the cost itself. A twelve-coil matrix, a programmable 1–100 Hz driver across multiple waveforms, a remote control and an LCD display all add cost that a higher single-coil wattage does not. The P91C at 200 W and the P91A at 240 W are different engineering answers, and comparing them on wattage alone systematically misprices both.
Should I buy the model with the most features for my first order?
Only if your market will pay for the features and your channel can explain them. A programmable multi-waveform device needs a demonstration and a trained seller; an automatic-sensing device sells itself to an older buyer with one sentence. The right first model is the one your sales process can actually support, and the additional features can be added on the second order once the channel is proven.
What single document most reliably reveals a cheap quote?
The test report. It reveals the model and voltage configuration the report was issued for, the standards applied, and the laboratory that issued it. A quote that cannot produce a report matching the exact configuration being sold is not necessarily a bad product, but it is an undocumented one, and the difference in price usually reflects exactly that.
How do I compare samples fairly?
Test them on the same day, with the same person, using the same session length, and record what you observed rather than what you felt. Uniformity across the footplate, surface temperature after a full session, noise, and the time it takes an unfamiliar user to start a session are the four observations that separate samples reliably. The golden sample and mass-production QC plan explains how to freeze the approved sample so production matches it.