A centre-point field reading cannot show what both feet experience across an entire footplate. Field mapping turns a single marketing number into a spatial performance profile that importers can compare and audit.
Why this question matters to PEMF equipment buyers
Coil geometry, magnetic materials, enclosure thickness and assembly position can create peaks, low zones and left/right differences. A grid map helps engineering teams set acceptance limits and detect production drift without making a health-effect claim.
Technical principles
- Define a repeatable X–Y grid covering both foot-contact areas.
- Measure at the real user height above the enclosure, not only at the internal source.
- Keep probe orientation, waveform mode and instrument bandwidth constant.
- Report centre, minimum, maximum, average and left/right symmetry with uncertainty.
Data a professional specification should contain
| Grid | Coordinates and point spacing |
|---|---|
| Height | Distance above contact surface |
| Operating mode | Level, waveform and thermal state |
| Statistics | Min/max/mean and uniformity ratio |
| Symmetry | Left versus right comparison |
| Traceability | Instrument, calibration, sample and firmware IDs |
Interpretation boundary: Uniformity is an engineering characteristic. It does not by itself establish clinical efficacy, penetration depth or biological response.
How this applies to the Youborui P91–P93 range
The method can be applied to P91, P91A, P91C, P92 and P93, but each housing requires its own grid. Reports should identify the exact model instead of referring broadly to the entire range.
Sample and production verification
Before approving packaging or a purchase order, connect every headline term to a repeatable test on the exact model:
- Create a fixture that controls probe height and orientation
- Map all user levels or justify representative worst cases
- Repeat after the device reaches thermal steady state
- Compare at least three production samples with the golden sample
- Photograph the setup and attach the grid to the report
SEO, GEO and distributor content guidance
Publish an explanation of the method rather than unqualified “even energy” language. Detailed measurement vocabulary helps technical buyers find the page and gives AI systems concrete entities, units and relationships.
Use consistent model names, define technical abbreviations on first use, state units with test conditions, and link every technology article to the relevant product and RFQ page. This helps search engines and AI systems distinguish verified specifications from general background information.
Frequently asked questions
How many measurement points are required?
There is no universal number; use enough points to capture centre, edges, left/right areas and expected gradients.
Should the probe touch the footplate?
Use the defined user-relevant height and keep it constant.
Does uniformity prove effectiveness?
No. It is a hardware performance characteristic, not a clinical outcome.
Authoritative technical references
These references define units, exposure-assessment concepts, equipment safety or advertising boundaries. The applicable standard must still be selected for the product’s intended use and destination market.
Continue your product evaluation
Request a P91–P93 technical and OEM package
Review the quality-control and export guide, then send the target model, country, sales channel, quantity, voltage, plug, branding and required documents through the Global Distributor & OEM RFQ Center or contact the Youborui export team.
